Rice-sized robots attempt to cure endocarditis.

At Johns Hopkins, two magnetic robots a few millimeters thick are delivering antibiotics to the heart to treat endocarditis, currently in a model.

Hand holding a red human heart model on a light background. Endocarditis.
Photo: DS stories / Pexels

It's 7,4 millimeters long and 2,8 millimeters wide, about the size of a grain of rice, and has no battery or motor. This small magnetic capsule is designed to enter the heart and deliver the antibiotic precisely where endocarditis is eating away at the inner lining and valves. It has a longer companion, armed with a needle, and together they form the pair of millirobots that a team of researchers from the Johns Hopkins University of Baltimore described in late September on Advanced Materials TechnologiesLet's say it right away, so we don't have to correct it later: there is no data on humans, nor on any living animal.

Endocarditis is a bacterial infection of the endocardium, the layer lining the heart's chambers. When it attacks the valves, it becomes seriously vicious: within one year of diagnosis, the average mortality rate is around 30%. In the United States, there are approximately 50.000 cases per year. Standard treatment involves four to six weeks of intravenous antibiotics, which, however, reach their target already diluted. So doctors often end up increasing the dose, with the risk of toxic effects, or resorting to cardiac surgery, which repairs the valve but often leaves room for a new infection.

The group is led by Anuruddha Bhattacharjee, then a postdoc at Hopkins and now a professor at the University of Alabama at Birmingham, and by the roboticist Axel KriegerTheir idea is simple: instead of diluting the drug throughout the body, deliver it to the patient's home. The question remains whether a system that works in a gel model will hold up inside a beating heart. It's best to keep this question in mind until the end.

Two magnetic modules against endocarditis: a needle and a capsule

The first robot is called needle module, needle module, and measures 2,8 by 12,1 millimeters: it reaches the infected area and temporarily implants itself in the heart wall with a needle equipped with hooks. According to the study, the hooks reduce the force required to penetrate a gel similar to cardiac tissue by 66,7%. From that moment on, the needle acts as a docking station. The second robot, the drug module, it's the drug capsule: it arrives, attaches to the needle with a magnet and releases the dose on the spot.

Both would enter the right atrium through a catheter. They would be guided wirelessly by electromagnetic coils placed on either side of the patient, with fields similar to those used in MRI. Krieger emphasizes this point: no onboard batteries or motors, because the thrust comes from outside. In a human, the robots would be monitored with fluoroscopy or ultrasound. Once their work is complete, they both detach and return to the catheter, which retrieves them.

The advantage of the modular concept lies in its repetition. The needle stays in place and the capsules shuttle back and forth, one dose after another, without having to start the journey inside the jars all over again. In 2022, we already counted half a dozen laboratory millirobots, including a 7,8-millimeter-wide Stanford origami. Four years later, none of them has entered a hospital ward. The Baltimore pair, however, is the first we've seen designed to work as a team against endocarditis, inside an organ that never stops working.

The measurements of the Johns Hopkins millirobots

Where it came out: Bhattacharjee A., Krieger A. and colleagues, Wireless Modular Millirobots With Magnetic Actuation for Targeted Cardiac Drug Delivery, its Advanced Materials Technologies, online from September 28, 2026. The authors are researchers from Johns Hopkins and the University of Maryland, together with the company Weinberg Medical Physics.

How wrong they are: The automatic guidance, aided by an artificial intelligence vision system, has an average error of 0,23 times the length of the needle module and 0,26 times that of the capsule. In millimeters, this is about 2-3.

How many times do they hook up: Docking was successful in 100% of the tests, and undocking in 93%.

Where they were tested: in a pulsed-flow agarose gel heart and in explanted porcine heart tissue. No live animals were used.

Baltimore's gel heart and the heart of a beating pig

For the tests, the group built a fake heart, a "phantom heart," cast in a silicone mold. The agarose gel was calibrated to have the consistency of human cardiac tissue. A pump pumps a pulsating flow through it, reproducing the rhythm of a real heart. However, the model has no valves and doesn't contract: it pumps without moving, a bit like a washing machine with a jammed drum that still spins.

Inside, the robots anchored themselves to the wall, hooked up, and then unhooked, under the eye of a camera that followed them in real time. They then moved on to a dissected pig heart, where the needle pierced real tissue and the capsule detached on command. "It's still in the prototype stage, but we see a lot of promise," Bhattacharjee said in an interview with MedscapeIn the same interview he admits that the system it has not yet been tested in a live animal.

Close-up of grains of white rice, the same size as the millirobots that fight endocarditis.
Photo: Ben Libby / Pexels

The Hopkins press release promises much more. Bhattacharjee says that with robots, "the entire procedure could take 10 minutes, maybe an hour if you want to do a couple of rounds." This would reduce the therapy from 4-6 weeks to a day or less. In the study, however, the capsule releases 22 microliters of drug in 180 minutesLet's do the math: that's three hours for a dose that fits in less than half a drop, given that a dropper drop is around 50 microliters.

Whether that half-drop is enough to sterilize a valve affected by endocarditis is beyond the scope of this study. There were no bacteria in the gel to kill. Even the 93% success rate should be interpreted with caution: in about 7 out of 100 trials, the capsule remained attached to the needle longer than expected. In a gel model, this is a finding that needs improvement; in a ventricle, it would become a nearly one-centimeter metal object that needs retrieval.

Simone Schürle, from Zurich, waits for the beating heart

Medscape asked for an opinion from Simone Schürle-Finke of the Swiss Federal Institute of Technology in Zurich, who did not participate in the study. The name should sound familiar. She is the researcher whose 8-micrometer magnetic microrobots dissolve clots 6 times faster than drugs, and therefore works on the same frontier with objects a thousand times smaller. She likes the cooperation between the two robots in the American work, namely their ability to dock, undock, and be retrieved, which could be useful in many biomedical applications.

The next step, for Bhattacharjee, is a more realistic fake heart, with contracting muscles and a chaotic flow like a real one. Then will come large animals, and only then humans. Optimistically, he says, the first trials could arrive in about five years. The process resembles that of Singapore's seed-sized surgical robot, which in May cut and sampled a chicken liver. For now, in short, these machines work on organs that are still.

On the road from a gel heart to actual endocarditis, the key quote to keep in mind is Schürle's: "This is an interesting engineering proof of concept, but important questions remain about the safety of these devices in a beating heart and their ability to effectively deliver the drug."